To analyze or to throw away? On the stability of excitation-emission matrices for different water systems
- Sandra Peer,
- Anastassia Vybornova,
- Joseph Tauber,
- Ernis Saracevic,
- Jörg Krampe,
- Matthias Zessner
- Vienna University of Technology,
- ,
Publikation:
Artikel i tidsskrift og konference artikel i tidsskrift
Tidsskriftartikel
Peer-reviewOpen Access
Publikation information
Produktionstype
Publikation:
Artikel i tidsskrift og konference artikel i tidsskrift
Tidsskriftartikel
Peer-reviewOriginalsprog
EngelskTidsskrift (Bind, Nummer)
Chemosphere (Bind 333)Publikationsmilepæle
- Udgivet - 08/2023
Publikationsstatus
Udgivet - 08/2023
ISSN
0045-6535Publication IDs
- Scopus: 85159174444
Resume
Fluorescence spectroscopy has numerous applications to characterize natural and human-influenced water bodies regarding dissolved organic matter (DOM) and contamination. Analyzing samples in a timely manner is crucial to gaining valid and reproducible excitation-emission matrices (EEM) but often difficult, specifically in transnational projects with long transport distances. In this study, eight samples of different water sources (tap water, differently polluted rivers, and wastewater treatment plant (WWTP) effluents) were stored under standardized conditions for 59 days and analyzed regularly. With this data set, the sample and fluorescence spectra stability was evaluated. Established analysis methods such as peak picking and fluorescence metrics were compared over time and benchmarked against dissolved organic carbon (DOC) and a maximal change of 10% in terms of their variability. Additional high-performance liquid chromatography (HPLC) data to identify single organic compounds provides insights into these DOM alterations and allows for conclusions about the underlying biological processes. Our results corroborate in a systematic way that the higher the organic or microbial load, the faster the sample must be processed. For all water sources, considerable changes were found between days zero and one, indicating a potential systematic bias between in-situ and laboratory measurements. The absolute signals of individual peaks vary substantially after only a few days. In contrast, relative metrics are robust for a much longer time. For specific metrics, when filtered and stored under cool and dark conditions, tap water may be stored for up to 59 days, non-polluted river water for up to 31–59 days, and WWTP effluents for up to 14–59 days. The storability thus depends both on the specific water source and the analytical plan. By systematizing our understanding of how the specific water source and DOM concentration determine the stability of samples during storage, these conclusions facilitate efforts to establish a standardized protocol.
Metrikker
PlumX, åbner i en ny fane
Citationer
4
Hentninger
17
Omtaler
1