Pupil Center as a Function of Pupil Diameter
- Zaheer Ahmed,
- Diako Mardanbegi,
Publikation:
Konference artikel i Proceeding eller bog/rapport kapitel
Konferencebidrag i proceedings
Forskning
Peer-reviewOpen Access
Resume
We investigate the gaze estimation error induced by pupil size changes using simulated data. We investigate the influence of pupil diameter changes on estimated gaze point error obtained by two gaze estimation models. Simulation data show that at wider viewing angles and at small eye-camera distances, error increases with increasing pupil sizes. The maximum error recorded for refracted pupil images is 2.4° of visual angle and 1.5° for non-refracted pupil projections.
Publikation information
Produktionstype
Publikation:
Konference artikel i Proceeding eller bog/rapport kapitel
Konferencebidrag i proceedings
Forskning
Peer-reviewOriginalsprog
EngelskSider fra-til (Antal sider)
Sider 283-286 (4 sider)Publikationsmilepæle
- Accepteret/In press - 14/12/2015
- Udgivet - 14/03/2016
Publikationsstatus
Udgivet - 14/03/2016
Forlag
Association for Computing Machinery, USAISBN (Trykt)
978-1-4503-4125-7Publikations IDer
- Scopus: 84975303243
Titel på værtspublikation
ETRA '16 Proceedings of the Ninth Biennial ACM Symposium on Eye Tracking Research & ApplicationsMetrikker
PlumX, åbner i en ny fane
Antal citationer
3
Hentninger
14
Adgang til dokumenter
Accepteret manuskript, 421.88 KB
Licens:Ikke-specificeret