Gå til søgefeltetSpring over til navigationSpring til hovedindhold

Low Cost vs. High-End Eye Tracking for Usability Testing

  • Sune Alstrup Johansen
    ,
  • Javier San Agustin
    ,
  • Henrik Tomra Skovsgaard Hegner Jensen
    ,
  • John Paulin Hansen
    ,
  • Martin Tall
  • Duke University
Publikation:
Konference artikel i Proceeding eller bog/rapport kapitel
Konferencebidrag i proceedings
Peer-review

Open Access

Resume

Accuracy of an open source remote eye tracking system and a state-of-the-art commercial eye tracker was measured 4 times during a usability test. Results from 9 participants showed both devices to be fairly stable over time, but the commercial tracker was more accurate with a mean error of 31 pixels against 59 pixels using the low cost system. This suggests that low cost eye tracking can become a viable alternative, when usability studies need not to distinguish between, for instance, particular words or menu items that participants are looking at, but only between larger areas-of-interest they pay attention to.

Publikation information

Produktionstype

Publikation:
Konference artikel i Proceeding eller bog/rapport kapitel
Konferencebidrag i proceedings
Peer-review

Originalsprog

Engelsk

Sider fra-til (Antal sider)

Sider 1177-1182 (6 sider)

Publikationsmilepæle

  • Udgivet - 07/05/2011

Publikationsstatus

Udgivet - 07/05/2011

Udgivelsessted

New York, NY, USA

Udgave

Extended Abstracts

Bind

CHI 2011

Forlag

Association for Computing Machinery, USA

ISBN (Elektronisk)

978-1-4503-0268-5

Publication IDs

  • Scopus: 79957970097

Titel på værtspublikation

Proceedings of the 2011 annual conference on Human factors in computing systems

Metrikker

PlumX, åbner i en ny fane

Hentninger
121
Citationer
36